国产无码176_色综合站激情五月天色_狼友视频在线观看剧情古装经典_黄片免费智_日韩精品人妻免费春色_24p亚洲一区_性爱亚洲黄色视频一区_成人网站@8禁_男女做暖视频18禁止_熟女精品播放_www.久久久_97精品一区区区_超碰人妻主页_久久悠悠影院_a片久久久

2020 官網(wǎng)升級中!現(xiàn)在您訪問官網(wǎng)的瀏覽器設(shè)備分辨率寬度低于1280px
請使用高分辨率寬度訪問。

Consultation hotline:400-021-6779

PRODUCT CENTER

PRODUCT CENTER

Voltage dips Generator

Single Phase 10A Voltage Dips Generator

Model:VDT S10

Voltage dips/sags, short interruptions are caused by failures of the power grid and power facilities or sudden large changes in loads. In some cases, there will be two or more consecutive dips or interruptions. Voltage changes are caused by continuous changes in the loads connected to the grid. If the EUT cannot respond in time to changes in the power supply voltage, it may cause malfunctions. Voltage dips generators are used to evaluate the performance of electrical and electronic equipment when subjected to voltage dips/sags, short interruptions, and voltage changes. Products fully meet the requirements of standards IEC/EN 61000-4-11 and GB/T17626.11.

Learn more

DC Voltage Dips Generator

Model:VDT DC

DC voltage dips and interruptions generator is a test device that simulates voltage dips, short interruptions, and voltage variations on DC input power port. VDT DC is specially designed for power fail simulation of DC systems. The product adopts a modular digital DC power supply system to provide customers with high-power DC output sources to meet the testing of different DC power systems. Products meet the requirements of standards IEC/EN 61000-4-29 and GB/T 17626.29.

Learn more

Three Phase 10A Voltage Dips Generator

Model:VDT T10

Voltage dips/sags, short interruptions are caused by failures of the power grid and power facilities or sudden large changes in loads. In some cases, there will be two or more consecutive dips or interruptions. Voltage changes are caused by continuous changes in the loads connected to the grid. If the EUT cannot respond in time to changes in the power supply voltage, it may cause malfunctions. Voltage dips generators are used to evaluate the performance of electrical and electronic equipment when subjected to voltage dips/sags, short interruptions, and voltage changes. Products fully meet the requirements of standards IEC/EN 61000-4-11 and GB/T17626.11.

Learn more

Single Phase 20A Voltage Dips Generator

Model:VDT S20

Voltage dips/sags, short interruptions are caused by failures of the power grid and power facilities or sudden large changes in loads. In some cases, there will be two or more consecutive dips or interruptions. Voltage changes are caused by continuous changes in the loads connected to the grid. If the EUT cannot respond in time to changes in the power supply voltage, it may cause malfunctions. Voltage dips generators are used to evaluate the performance of electrical and electronic equipment when subjected to voltage dips/sags, short interruptions, and voltage changes. Products fully meet the requirements of standards IEC/EN 61000-4-11 and GB/T17626.11.

Learn more

Three Phase 20A Voltage Dips Generator

Model:VDT T20

Voltage dips/sags, short interruptions are caused by failures of the power grid and power facilities or sudden large changes in loads. In some cases, there will be two or more consecutive dips or interruptions. Voltage changes are caused by continuous changes in the loads connected to the grid. If the EUT cannot respond in time to changes in the power supply voltage, it may cause malfunctions. Voltage dips generators are used to evaluate the performance of electrical and electronic equipment when subjected to voltage dips/sags, short interruptions, and voltage changes. Products fully meet the requirements of standards IEC/EN 61000-4-11 and GB/T17626.11.

Learn more